Fitting out a commercial kitchen involves more than satisfying the wants of the chef. There are a number of building regulations which have to be adhered to by the designer and these need to be adhered to from the start to avoid expensive alterations later.
Fire Safety and Part B
This area of the building regulations covers Fire Safety and Part B must be given particular consideration in a kitchen full of heat, oil and flames. Fire rated walls and doors are often required to be contained within the kitchen and prevent the spread of fire into dining areas and escape routes. Ductwork and vents within kitchens containing extraction systems also must be of a fire resistant material for the full length of the duct and pass through other rooms on different floors without breaching fire resisting construction. Access to escape routes must at all times be kept clear of obstructions including equipment, waste bins and stores.
Ventilation Under Part F
Part F states that you must provide adequate ventilation by means of mechanical extraction and by providing adequate makeup air to prevent the kitchen returning to atmospheric pressure and suffering from the ingress of cold air which can cause discomfort and can also affect the performance of extraction fans and the combustion of gas appliances.
Energy Efficiency and Part L
Efficiency – Part L – commercial kitchens need to be well insulated, and all equipment chosen with efficiency in mind. Remember that a poor efficiency rating on items such as combi ovens and refrigeration units can cost a lot of money to run on a daily basis, and it is likely to cost more in the long term than more expensive items that are more efficient.
Drainage, Waste Water and Grease
Drainage: Waste water and Grease – Part H – Building Regulations. Grease can solidify in waste water pipes and cause problems in sewerage systems. In order to prevent this type of problem a grease trap needs to be installed at the correct point in the drainage system. In addition to this the flow of the kitchen waste water needs to be sufficient for the expected volume of peak hour usage. An under sized system can lead to part of the system blocking up and causing a mess in the kitchen at the worst time.
Gas Safety and Combustion Air

The regulation for gas appliances in commercial kitchens is Part J of the building regulations for combustion, and the flues from gas appliances. This needs to be installed by a Gas Safe registered engineer, and covered by the health and safety guidance for catering businesses. In particular, fire and health risks from gas appliances need to be highlighted as key workplace risks in a catering environment, along with burns, slips and manual handling. When planning out the kitchen, the routes of the flues from gas appliances and the provision of adequate combustion air need to be considered, not as an afterthought once appliances have been chosen.
Accessibility Under Part M
Part M deals with accessibility in building. For a workplace like a commercial kitchen for example staff access must meet the requirements of Part M for commercial spaces as well as customer access for public spaces. That means door widths for staff to pass through with trolleys as well as wheelchair users, work surface height to suit the users, and minimum width of walkways between sections of equipment etc. As with the other parts these requirements must be designed in from the start as adding wider doors or even making a section of a kitchen adjustable to different heights can be very costly to put in after the kitchen has been fitted out.
Checking What Needs Sign-Off
While not all kitchen work needs to go through Building Control, like-for-like change of equipment or minor cosmetic changes to a kitchen are likely to be subject to Permitted Development. Minor changes such as relocation of equipment or minor modification to the distribution of kitchen items would also likely to be subject to Permitted Development. For larger kitchen alterations such as new extraction ductwork, changes to fire compartmentation, or any work affecting drainage, full approval would be required via Building Control. It is always best to check with your local Building Control team before commencing work to confirm what is required by your local authority for your specific project and to get confirmation in writing of what is required.
Designing Compliance In From the Start
Many people don’t realise that ensuring commercial Kitchen Design to comply with Building Regulations also has to comply with Food Hygiene and HACCP requirements. In many cases surface finishes to comply with fire regulations also need to comply with food safety for commercial kitchens using cleanable, non-porous materials. Trying to add these compliance requirements after a design has been fixed can result in costly rework.
If you are looking for Commercial Kitchen Design, see Target Catering.
Treating the building regulations for your commercial kitchen as part of the design for your kitchen from the very beginning will result in a safer working environment, reduced operating costs and fewer unexpected problems when inspected by the authorities.